Clamping forces for collets
8.6
The force Fy tends to tip the work piece out of the collet bore, when the clamping length is short (L1 <
D1). To prevent this you must increase the axial force Ft by the factor b.
L L
1 2
½ F
m n
2
a, m
1 M
x
D
2
F D
t 1
F
x
F
y
½ F
n
2M 2 μ = 0.05¸ 0.3
βs x 2 1
F = + F (tanα + μ )
t μ D x 1 for work pieces in steel :
2 1
μ = 0.05 ¸ 0.3 with smooth bore
2
0.2¸ 0.4 with grooved bore
0.3¸ 0.6 with serrated bore
s = 1.2 ¸ 1.5
Influence of F in relation with
y
the distance to the collet L 2
12
10
8
b 6
4
2
0
0.5 1 1.5 2 2.5 3 3.5 4
L /D 1